10.1515/aoa-2015-0031
Mutually Orthogonal Golay Complementary Sequences in Synthetic Aperture Imaging Systems
The paper presents the preliminary results of computer simulation of the synthetic aperture method combined with the orthogonal Golay sequences in a linear transducer array. The transmission of long waveforms characterized by a particular autocorrelation function allows to increase the total energy of the transmitted signal without increasing the peak pressure. It can also improve the signal-to-noise ratio and increase the visualization depth maintaining the ultrasound image resolution.
In the work, the 128-element linear transducer array with a 0.3 mm pitch excited by 8-bits Golay coded sequences as well as one cycle at nominal frequencies of 4 MHz were used. The comparison of 2D ultrasound images of the phantoms is presented to demonstrate the benefits of a coded transmission. The image reconstruction was performed using the synthetic STA algorithm with transmit and receive signals correction based on a single element directivity function.
References
CHIAO R.Y. and THOMAS L.J. (2000), Synthetic transmit aperture imaging using orthogonal Golay coded excitation, Proc. IEEE Ultrason. Symp., 1677-1680.
GOLAY M.J.E. (1961), Complementary series, IRE Tran. Inf. Theory, IT-7, 82–87.
HUANG X. (2005), Simple implementations of mutually orthogonal complementary sets of sequences, Proc. International Symposium on Intelligent Signal Processing and Communication Systems, 369–372.
KLIMONDA Z., LEWANDOWSKI M., NOWICKI A., TROTS I. (2005), Direct and post-compressed sound fields for different coded excitations – experimental results, Archives of Acoustics, 30, 4, 507–514.
NOWICKI A., SECOMSKI W., LITNIEWSKI J., TROTS I. (2003), On the application of signal compression using Golay’s codes sequences in ultrasound diagnostic, Archives of Acoustics, 28, 4, 313–324.
PENG H., HAN X., LU J.(2006), Study on application of complementary Golay code into high frame rate ultrasonic imaging system, Ultrasonics 44, e93–e96.
TROTS I., NOWICKI A., SECOMSKI W., LITNIEWSKI J. (2004), Golay sequences – side-lobe canceling codes for ultrasonography, Archives of Acoustics, 29, 1, 87–97.
TROTS I., NOWICKI A., LEWANDOWSKI M. (2009), Synthetic transmit aperture in ultrasound imaging, Archives of Acoustics, 34, 4, 685 – 695.
TROTS I., NOWICKI A., LEWANDOWSKI M., TASINKEVYCH Y. (2010), Multi-element synthetic transmit aperture in medical ultrasound imaging, Archives of Acoustics, 35, 4, 687 – 699.
TSENG, C.C. and LIU, C.L. (1972), Complementary sets of sequences, IEEE Trans. Info. Theory, IT-18, 644-652.
DOI: 10.1515/aoa-2015-0031