Archives of Acoustics, 8, 2, pp. 139-154, 1983

Evaluation of electroacoustic devices by the equivalent scale methods

Toniasz ŁĘTOWSKI
Laboratory of Music Acoustics, Chopin Academy of Music
Poland

Jacek SMURZYŃSKI
Laboratory of Music Acoustics, Chopin Academy of Music
Poland

This paper presents the preliminary results of experiments on the possibility of using methods based on the mutual masking of signals compared, in auditory evaluation. An attempt was made to objectivize the measure of the similarity of the signals, or the transmission channel quality, and to evaluate the degree of differentiation of objects investigated on an equivalent physical scale. In the preliminary experiments a number of experimental procedures were examined, two of which, characterized by the relatively highest differentiation sensitivity, underwent more detailed evaluation. The results indicated the possibility of objectivizing the measure of the transmission circuit quality in the range of frequency response variation over a third-octave.
Full Text: PDF
Copyright © Polish Academy of Sciences & Institute of Fundamental Technological Research (IPPT PAN).

References

C. BORDENE-SACERDOTE, C. MODENA, Prove d’ascolio su sistemi di altoparlanti, Elettronica a Telecomunicazioni, 6, 1-20 (1971).

B. W. KULESZA, Method of auditory evaluation of radio sets in industrial conditions (in Polish), Proc. XXII Open Seminar on Acoustics, Świeradów 1975.

T. ŁĘTOWSKI, Auditory evaluation of electroacoustic devices (in Polish), Zesz. Nauk. PRiTV, 27 (1976).